Abstract

For the masticatory system to be functioning, the maximum voluntary biting force must be evaluated. It is impossible to find a special solution that combines desired qualities like dependability, accuracy, precision, usability, and comfort. This is because a number of factors affect the estimation of  this force. This page lists the various tools available for measuring bite force.

Article Details

How to Cite
Pallavi Mundra, Rajeev Srivastava, Sourabh Khandelwal, Raveena Makker, Vedant Patel, & Nency Parihar. (2023). Bite force part II – Devices. Journal of Coastal Life Medicine, 11(2), 568–572. Retrieved from https://www.jclmm.com/index.php/journal/article/view/1049
Section
Articles

References

J. F. Bates, G. D. Stafford, and A. Harrison, “Masticatory function—a review of the literature. 1. The form of the masticatory cycle,” J. Oral Rehabil. 2(3), 281–301 (1975).

Kim, J. H., Han, J. H., Park, C. W., and Min, N. K. (2020). Enhancement of withstand voltage in silicon strain gauges using a thin alkali-free glass. Sensors (Basel) 20:3024. doi: 10.3390/s20113024

Fernandes, C. P., Glantz, P.-O. J., Svensson, S. A., and Bergmark, A. (2003). A novel sensor for bite force determinations. Dent. Mater. 19, 118–126. doi: 10.1016/s0109-5641(02)00020-9.

Braun, S., Hnat, W. P., Freudenthaler, J. W., Marcotte, M. R., Honigle, K., and Johnson, B. E. (1996). A study of maximum bite force during growth and development. Angle Orthod. 66, 261–264.

Chen, M., Luo, W., Xu, Z., Zhang, X., Xie, B., Wang, G., et al. (2019). An ultrahigh resolution pressure sensor based on percolative metal nanoparticle arrays. Nat. Commun. 10:4024

Sattayasoonthorn, P., Suthakorn, J., and Chamnanvej, S. (2019). On the feasibility of a liquid crystal polymer pressure sensor for intracranial pressure measurement. Biomed. Tech. (Berl.) 64, 543–553. doi: 10.1515/bmt-2018-0029

Peng, X., Hu, L., Liu, W., and Fu, X. (2020). Model-based analysis and regulating approach of air-coupled transducers with spurious resonance. Sensors (Basel) 20:6184. doi: 10.3390/s20216184

Zhu, P., Peng, H., Mao, L., and Tian, J. (2020). Piezoelectric single crystal ultrasonic transducer for endoscopic drug release in gastric mucosa. IEEE Trans. Ultrason. Ferroelectr. Freq. Control doi: 10.1109/TUFFC.2020.3026320 [Epub ahead of print].

Kerstein RB, Lowe M, Harty M, Radke J. A force reproduction analysis of two recording sensors of a computerized occlusal analysis system. CRANIO®. 2006;24(1):15–24.

Lyons MF, Sharkey SW, Lamey P-J. An evaluation of the T-Scan computerised occlusal analysis system. Int J Prosthodont. 1991;5(2):166–72.

Misirlioglu M, Nalcaci R, Baran I, Adisen MZ, Yilmaz S. A possible association of idiopathic osteosclerosis with excessive occlusal forces. Quintessence IntBerlGer 1985. 2014;45(3):251–58.

D. Koc, A. Dogan, and B. Bek, “Bite force and influential factors on bite force measurements: a literature review,” Eur. J. Dent. 4, 223–232 (2010).

Tatematsu M, Mori T, Kawaguchi T, Takeuchi K, Hattori M, Morita I, et al. Masticatory performance in 80-year-old individuals. Gerodontology. 2004;21(2):112–19.

Shinogaya T, Bakke M, Thomsen CE, Vilmann A, Matsumoto M. Bite force and occlusal load in healthy young subjects–a methodological study. Eur J ProsthodontRestor Dent. 2000;8(1):11–15.

Tzakis MG, Österberg T, Carlsson GE. A study of some masticatory functions in 90-year old subjects. Gerodontology. 1994;11(1):25–29.

Palinkas M, Nassar MSP, Cecílio FA, Siéssere S, Semprini M, Machado-deSousa JP, et al. Age and gender influence on maximal bite force and masticatory muscles thickness. Arch Oral Biol. 2010;55(10):797–802.

Kogawa EM, Calderon PS, Lauris JRP, Araujo CRP, Conti PCR. Evaluation of maximal bite force in temporomandibular disorders patients. J Oral Rehabil. 2006;33(8):559–65.

VermaT ,Kumathalli KI, Jain V, Kumar R. Bite Force Recording Devices - A Review. Journal of Clinical and Diagnostic Research. 2017 Sep, Vol-11(9): ZE01-ZE05

Serra MD, Gambareli FR, Gavião MBD. A 1–year Intraindividual Evaluation of Maximum Bite Force in Children Wearing a Removable Partial Dental Prosthesis. J Dent Child. 2007;74(3):171–76.

Pereira LJ, Gavião MBD, Bonjardim LR, Castelo PM, Van der Bilt A. Muscle thickness, bite force, and craniofacial dimensions in adolescents with signs and symptoms of temporomandibular dysfunction. Eur J Orthod. 2007;29(1):72–78.

Freeman PW, Lemen CA. Measuring Bite Force in Small Mammals with a Piezoresistive Sensor. ResearchGate [Internet]. 2008 Apr 1 [cited 2017 Jan 10];89(2). Available from: https://www.researchgate.net/publication/228788828_ Measuring_Bite_Force_in_Small_Mammals_with_a_Piezo-resistive_Sensor

Kan JP, Judge RB, Palamara JE. In vitro bone strain analysis of implant following occlusal overload. Clin Oral Implants Res. 2014;25(2):e73–82.

Similar Articles

You may also start an advanced similarity search for this article.